Impeller flow meter
FS series Fluorine resin body
- No elution such as organic carbon and metal ion, fluorine resin body of high durability.
- For weight, it is not too burdening to the piping.
- It is compatible with various liquids, ideal for pure water piping, chemicals piping.
- Compatible models: FS-S / FS-AR / FS-N
Each specification, the same as the standard.
Differences in the material and structure, see the following "Material / structure".
Contact us for CAD data and instructions.
* Descriptions are based on Japanese Industrial Standards (JIS)
|
Specifications |
Model |
FS-3 |
FS-10 |
FS-30 |
Flow range |
0.5-3 L/min |
1.5-10 L/min |
5-30 L/min |
Fluid |
Various liquids |
Maximum working pressure |
0.5 MPa |
Flow temperature |
0-90C° (No freezing, No dewing) |
Ambient temperature |
0-40C° (No freezing, No dewing) |
O-ring for sealing |
Fluoro rubber |
Wetted material |
Fluorine resin, Ceramic |
Adapter connection size |
Rc1/2 or Rc3/8 or φ10×12mm *1 |
Connection material |
SUS/BsBM (Ni plating) / Fluorine resin |
Mounting position |
Free |
Flow direction |
Both direction |
Weight |
Aprrox. 380g |
Construction |
Water drip-proof against electronic circuit |
How to Order has a different model type.
If you have any query regarding our products or services, please feel free to contact us.
*1 In the case of φ10 × 12mm, material is fluorine resin.
TEL: +81-42 756 7567
FAX: +81-42 752 2004
Email: info@rgl.co.jp